Error Code E iS
Defect of ice-room or ice maker sensor
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check CON3 10th-to-9th-pin: if 0 Ω, sensor shorted — replace ice-room sensor.
- 2
If OL/open — go to step 3.
- 3
Check sensor resistance against temperature table (40 kΩ at -22°F, 30 kΩ at -13°F, 23 kΩ at -4°F, 17 kΩ at 5°F, 13 kΩ at 14°F, 10 kΩ at 23°F, 8 kΩ at 32°F). If out of range, replace sensor.
- 4
Check connector between Main PCB and ice-room sensor — reconnect or repair.
- 5
If connector OK and error persists, explain to customer or replace Main PCB.
This Error Applies To
LG LRYKC2606 Series Refrigerators
Related Error Codes
Defect of pantry sensor
Defect of freezer defrosting sensor
Defect of Mini Cubed ice maker sensor
Defect of freezer craft ice maker kit
Sub PCB communication error
Defect of room temperature (RT) sensor
Defect of freezer craft ice maker sensor
Defect of ice maker kit (in-door icemaker motor malfunction)